Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.
Split type electromagnetic flowmeter
The split type electromagnetic flowmeter is composed of two parts: electromagnetic flow sensor and electromagnetic flow converter. The sensor is mounted on the pipe to detect the flow of the fluid, and the converter is responsible for converting the signal of the sensor into a readable flow value. This structure makes the installation and maintenance of the instrument more convenient, while also reducing the resistance of the fluid flow, which is suitable for the flow measurement needs of different processes. one
Several faults of electromagnetic flowmeter and processing ideas and methods
First, according to the fault occurrence period If problems occur during the installation and commissioning period, the following analysis and inspection should be focused on: 1. Whether the operating conditions of the instrument meet the requirements 2. Whether the instrument selection is correct
Metal rotameter different fluid installation methods
Most metal rotameters must be mounted vertically on a vibration-free pipe and should not be significantly tilted, with fluid flowing through the instrument from bottom to top. The instrument has no mandatory requirements for the length of the upstream straight pipe section, and in the actual installation process, we also need to master the different installation methods of different fluids, the following is a detailed introduction: 1, for the installation of dirty fluids: a filter should be i
Electromagnetic flowmeter common fault analysis and measures
Electromagnetic flowmeter common fault analysis and measures 1, electromagnetic flowmeter display minimum or no display The sensor has no flow signal output. The reasons are power failure, connection cable failure; Sensor or converter components are damaged; The reasons for the process include the change of liquid flow condition and the problem of the adhesion layer on the inner wall of the process pipeline. It can be checked
Flowmeter accuracy and repeatability
Flow sensors can also be called flowmeters, flowmeters are mainly used to measure gas, liquid and other flow such as volume or mass in the channel. The selection of the appropriate flowmeter has a great influence on the measurement results of the experiment. So, how to choose the right flowmeter? In fact, the choice of flow timing should first look at the flow meter specifications. Second, two important flowmeter statistics should be focused on: accuracy and repeatability. Accuracy of flowmet
Hydraulic flowmeter selection Guide
01 What is traffic? Flow rate is the volume of fluid flowing through a fixed point per unit time. For most hydraulic applications, flow is measured in liters per minute (L/min), US gallons per minute (US gpm) or sometimes, British gallons per minute (UK gpm). picture highlight 02
Flowmeter failure in sewage treatment, how to deal with
Electromagnetic flowmeter, as a kind of precise flow measuring instrument, has been widely used in practical industrial production because of its good measuring effect on conductive liquid. We often use it in sewage treatment, but in the daily flow measurement, due to the existence of a variety of factors, it is easy to appear in the use of the table head is not bright, the number is unstable, fluctuations, inaccurate and other failures. So what should we deal with after the troubleshooting occurs? picture
Product introduction - Radar current flow meter
Application scenario Radar flow meter is suitable for non-contact velocity, water level and flow measurement in river, irrigation channel, underground drainage pipe network, flood prevention and early warning. The product has the characteristics of low power consumption, small size, high reliability and easy maintenance. The measurement process is not affected by temperature, sediment, river pollutants, floating objects on the surface and other factors. &nb
Five key contents of instrument daily maintenance
The daily maintenance of process testing and control instruments is a very important work, which is an indispensable part of many links to ensure the safety and smooth operation of production. The daily maintenance of instruments reflects the idea of total quality management and prevention first. The instrument workers should seriously do the daily maintenance work of instruments to ensure the normal operation of instruments. Instrument routine maintenance focuses on the following five work contents:
Distillation system steam flow metering instrument selection
Distillation system steam flow metering instrument selection Steam has a high heat capacity and is one of the most widely used heat carriers that can be transferred over long distances. For the rectification system, the heat consumption accounts for more than 30% of the operating cost, usually the medium of input heat is steam, from the perspective of energy saving and consumption reduction, accurate guidance of the energy consumption of the rectification system, not only can be more accurate control of the re
The rotameter shows troubleshooting of reduced flow rate
Rotameter is a kind of constant pressure drop variable flow cross-area flowmeter, which is composed of a conical tube and a rotor (also known as a float) placed in a conical tube that can move freely up and down Nitrogen flowmeter FT-1204A flowmeter, open this flowmeter shows 400Nm³/h, the master meter shows flow reduction, the utility master meter shows 0, open bypass, the master meter and the utility master meter shows normal (500Nm³/h).
Why can't we choose the vortex flowmeter diameter according to the process pipe?
Vortex flowmeters have been debugged and calibrated before leaving the factory, and the flow coefficient of each instrument is not the same. Therefore, in the selection should be based on the flow range provided by the manufacturer (generally m3/h) to determine the instrument caliber, when the measured medium conditions and the conditions provided by the manufacturer do not match, especially when the medium density and viscosity do not match; The lower limit flow rate should be determined by calculation, and t
In the process of industrial production, do not look at the instrument is inconspicuous, but it is the most indispensable! The following is to introduce the selection of flow meters. (1) General principles 1 Scale selection The instrument scale should meet the requirements of t
30 common faults of field instrument and treatment
Instrument problems, the reasons are more complex, it is difficult to find the crux of the problem, then calm and calm, segmented analysis, the first analysis of the reasons in that unit, can be roughly divided into three segments: field detection, intermediate transmission, terminal display; At the same time also consider the seasonal reasons, summer temperature is too high, winter anti-freeze; When the parameters involved in the adjustment are abnormal, the regulator is first switched to the manual state, and the reason is observed and analyzed whether the
Small signal excision in flow meter
Through the analysis of flow measurement principle, field conditions and measurement requirements, the flow meter is selected correctly, so that the performance of the selected instrument can meet the requirements of the actual operation parameters, and the purpose of accurate measurement is achieved. Based on the working practice, this paper discusses the optimization of small signal excision of flow measuring instrument. picture picture
Maintenance of differential pressure flowmeter
The working principle and structure of differential pressure flowmeter Differential pressure flowmeter measurement system as shown in the figure above, fluid flow in the pipeline, through the throttling device, due to the sudden reduction of flow area, the flow rate will inevitably produce local contraction, speed up the flow rate, according to the principle of conservation of energy, dynamic pressure and static pressure energy can be converted to each othe
What are the applications and characteristics of intelligent precession vortex flowmeters?
1. Application scope It can be widely used in petroleum, chemical industry, electric power, coal metallurgy, urban gas supply and other industries, for measuring gas flow such as compressed air, hydrogen, argon, oxygen, nitrogen, natural gas, liquefied gas and so on. Especially in the oil field and city gas transmission and distribution metering and trade metering, intelligent precession vortex flow meter is the first choice.
Flow meter measurement knowledge
1. What is traffic? What are the two categories? Flow rate is the amount of fluid flowing through a section of a pipe per unit time. It is divided into volume flow and mass flow. 2, with the orifice plate to measure the flow, why is it reasonable to install the orifice plate in front of the regulating valve? In the theoretica
Electromagnetic flowmeter is a kind of induction meter according to Faraday's law of electromagnetic induction to measure the volume flow of conductive medium in the tube. After years of development, electromagnetic flowmeter has formed many kinds. Electromagnetic flowmeters are widely used in modern industry, energy metering, environmental protection engineering, transportation, biopharmaceutical, scientific experiments, ocean images, rivers and lakes measurement and other fields. Electromagnetic flowmeter is a kind of induction meter according to Faraday's
1. Installation of source components (A) temperature source components 1, the installation location of the temperature source parts should be selected in the medium temperature changes sensitive and representative of the place, should not be selected in the valve and other resistance parts and the medium flow rate into the dead Angle and the place where the vibration is large. 2. The installation position of th
Advantages and disadvantages of precession vortex flowmeter
There are often customer feedback that some people use gas turbine flowmeters to measure natural gas, and some people use precession vortex flowmeters to measure natural gas flow, so what is the difference between the two? To answer this question, we must first recognize the advantages and disadvantages of precession vortex flowmeters: First, precession vortex flowmeter introduction: Precession vortex flowmeter is another type of fluid vibratio
Flow measuring instrument principle, classification and selection overview
Flow detection and instrumentation is a type of instrument designed to measure the flow or total amount of fluid passing through a pipe or equipment per unit time. These instruments are widely used in various industrial production process control, energy management, environmental protection, transportation, scientific research and other fields, and are essential for monitoring and regulating the flow of fluids such as liquids, gases or steam. I. Classification
The principle and method of various flowmeter selection
The principle of selecting flow meters is first to deeply understand the structural principles and fluid characteristics of various flow meters, and at the same time to choose according to the specific situation of the site and the surrounding environmental conditions. There are economic considerations, too. Under normal circumstances, mainly from the following five aspects to choose: ① Performance requirements of flowmeter; ② Fluid characteristics;
Flow rate is an important parameter in natural gas production. Flow rate is the amount of fluid passing through a certain cross-sectional area per unit time. Flow is divided into instantaneous flow and cumulative flow. Instantaneous flow refers to the amount of fluid flowing through a section of the pipeline in a unit time, referred to as flow. Cumulative flow refers to the sum of the number of fluids flowing through the pipeline in a certain period of time, that is, the cumulative value of the instantaneous flow
Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.
Fill in more information so that we can get in touch with you faster
Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.